The gear driven cable operated damper is mounted upstream of the air device with the control cable inside or outside of the airstream.

Anemostat cable operated damper.

Damper with flexible cable for remote adjustment. Factory welded to neck. Operating mechanism provides for a positive damper setting in a position from fully opened to fully close rotating blades are tensioned with music wire to maintain setting and prevent rattling 24 x 24 is maximum one piece construction. Ob7s same construction features as the ob1 damper but with a flexible cable directly attached to the damper.

View more vibro acoustics manufacturers of fine acoustical products. No wall or ceiling penetrations are required. Cable is routed inside the ductwork and terminated at the diffuser face. The blades are conveniently adjusted from the room side of the diffuser and are designed to hold their position indefinitely.

Flex duct bends may interfere with operation of damper and is not recommended. Flex duct bends may interfere with operation of damper and is not recommended. The ld louver damper can be added to any anemostat round neck diffuser or sra square to round adapter. Engineered custom acoustic solutions silencers attenuators for the entire industry acoustical barriers plenums acoustic plenums.

Airflow balancing and damper adjustment is performed at the face of the diffuser. Stainless steel front operated opposed blade volume control damper model ob1. 5 32 hex key required. The damper is adjusted via rotary cable actuation using a nut driver or flat head screwdriver.

The actuator at the end of the adjustment cable is accessible from the diffuser grille internal or is routed to an appropriate area such as a wall mount external. The vd damper can be added to any anemostat round neck diffuser or sra square to round adapter. Vav damper belimo lmb24sr motor w 2 10vdc 3045. Airflow balancing and damper adjustment are performed at the face of the diffuser.

Vav damper auto changeover w relay. Multiple dampers used for large sizes. Anemostat a mestek company architectural specialty air distribution products air discharge jet nozzles. Medium pressure vav damper belimo lmb motor 2085.

Damper is adjusted via rotary cable actuation using a nut driver or flat head screwdriver. This damper uses a worm gear mechanism requiring minimal torque at the end of the cable and is ideal for longer cable lengths tighter cable bend radii and larger dampers. After balancing is complete the cable is recessed behind the diffuser.

Durodyne

Durodyne

Anemostat Pvv Electronic Vav Diffuser

Anemostat Pvv Electronic Vav Diffuser

Anemostat Qst Fan Powered Series Air Terminals

Anemostat Qst Fan Powered Series Air Terminals

Http Www Anemostat Com A Catalog Literature Controls Manual Cm1 Pdf

Http Www Anemostat Com A Catalog Literature Controls Manual Cm1 Pdf

Source : pinterest.com